RESUMEN
PURPOSE: To determine the effects of prostatic artery embolization (PAE) on prostate elasticity as assessed using ultrasound elastography (US-E) and to describe baseline US-E's potential role in patient selection. MATERIALS AND METHODS: This was a prospective investigation that included 20 patients undergoing PAE to treat lower urinary tract symptoms attributed to benign prostatic hyperplasia (BPH). US-E with measurement of the prostatic elastic modulus (EM) and shear wave velocity (SWV) was performed before PAE and at 1-month follow-up. Baseline, 3-month, and 1-year follow-up evaluations included prostate-specific antigen, uroflowmetry, pelvic magnetic resonance imaging, and clinical assessment using the International Prostate Symptom Score (IPSS) and quality of life (QoL) metrics. RESULTS: Seventeen patients entered statistical analysis. US-E showed a significant reduction in mean prostatic EM (34.4 kPa vs 46.3 kPa, -24.7%, P < .0001) and SWV (3.55 m/s vs 4.46 m/s, -20.0%, P < .0001) after PAE. There were moderate positive correlations between baseline EM and 1-year IPSS (R = 0.62, P = .007) and between baseline SWV and 1-year IPSS (R = 0.68, P = .002). Baseline SWV ≥ 5.59 m/s and baseline EM ≥ 50.14 kPa were associated with suboptimal IPSS and QoL outcomes after PAE with high degrees of sensitivity (100%) and specificity (69-100%). CONCLUSIONS: PAE led to a positive effect on the BPH dynamic component related to prostatic elasticity. There was a moderate positive correlation between baseline prostatic elastographic parameters and 12-month IPSS. Measurement of baseline elastographic characteristics may become useful for the evaluation and selection of patients for PAE.